Orders & Worldwide
Orders & Worldwide
In the complex world of industrial automation, ABB servo drives are renowned for their precision and reliability. However, like any sophisticated machine, they can occasionally encounter problems that require maintenance or repair.
This guide is designed to provide technicians and engineers with a comprehensive understanding of common maintenance practices and a detailed overview of alarm codes associated with ABB servo drives. Armed with this knowledge, you will be able to effectively diagnose, troubleshoot and resolve a wide range of issues, ensuring that your robotic systems remain operational and efficient.
Let's delve into the essential methods for maintaining ABB drives and decipher the meaning behind the most common alarm codes.
1. Inspect the alarm fault codes and fault logs. Since the drive unit will display corresponding codes after a fault occurs, and different codes represent different faults, maintenance personnel can roughly determine the fault range of the servo drive unit through these fault codes.
2. Measure the voltage signals and power-on signals based on the fault phenomena. After the equipment fails, the fault location can be judged according to the fault phenomena, and then the voltage signals and continuity signals at the corresponding positions are measured. The main focus is to check whether the voltage signals and power signals are normal to find the real cause of the fault.
3. Determine the cause of the fault by detecting voltage and communication methods.
4. Measure the quality of the IGBT and brake resistors. Also, it is possible to measure whether the control lines are loose or if there are any arcing traces. Since these are the main reasons for drive failures, starting from these aspects can effectively shorten the repair time.
5. Replacement method. After the equipment fails, the fault can be excluded by the replacement method. That is, use a normal part to replace the suspected damaged part. If the equipment can return to normal operation after replacement, it can be determined that the original part is damaged.
Common fault repairs for ABB robot servo drive units include: motor phase short circuit, motor current rectifier start error, leakage resistor circuit short, unknown drive unit class, drive unit severe temperature error, missing drive unit, internal error of the drive unit, etc.
34200 Communication interrupted with all drive units
34202 Communication interrupted with ABB robot drive unit
34267 Too many rectifiers connected
34300 Unknown drive unit type
34306 ABB robot drive unit temperature error
34307 Drive unit temperature warning
34308 Drive unit severe temperature error
34309 Drive transistor current too high
34311 Drive converter saturation warning
34312 Missing drive device
34313 Incorrect drive unit type
34314 ABB robot servo drive node missing
34318 Drive converter saturation error
34319 Critical error in the drive device
34320 Too many drive nodes connected
34406 Drive device power supply error
34407 Drive unit internal error
34408 Drive unit hardware data error
34409 Drive device startup error
34410 Too many ABB robot drive units connected
39407 Drive unit type code error
39410 Drive unit communication alarm
39411 Too many communication errors
39413 Drive not synchronized
39415 Communication interrupted with drive unit
39416 Drive unit unresponsive
39418 Unknown drive unit type code
39420 Drive unit built-in test failed
Fault Phenomenon: The drive unit for contact arg reports a short circuit. The contact is connected with the unit position arg and node arg of the drive module arg.
Cause:
Recommended Action:
Fault Phenomenon: For joint arg, the current controller detects a significant deviation in the motor's torque current. The joint is connected to the drive unit in the drive module arg, unit position arg, node arg.
Cause:
Recommended Action:
Fault Phenomenon: In the drive module arg, the inrush control relay in the rectifier unit at the drive unit position arg has given an error indication.
Cause:
This may be caused by a malfunction of the inrush control relay in the rectifier.
Recommended Action:
Restart the system and try again. If the problem persists, replace the unit.
Fault Phenomenon: In the drive module arg, the bleeder resistor connected to the rectifier unit at the drive unit position arg indicates a short circuit.
Cause:
This may be due to a fault in the bleeder resistor or its cables.
Recommended Action:
Fault Phenomenon: In the drive module arg, the DC link voltage of the drive unit located at unit position arg is approaching the lower limit.
Cause:
The input power supply voltage of the rectifier unit is out of specification.
Recommended Action:
{"one"=>"Wählen Sie 2 oder 3 Artikel zum Vergleichen aus", "other"=>"{{ count }} von 3 Elementen ausgewählt"}
Wählen Sie das erste zu vergleichende Element aus
Wählen Sie das zweite zu vergleichende Element aus
Wählen Sie das dritte Element zum Vergleichen aus
Einen Kommentar hinterlassen